600 Kw Load Bank

600 kW load bank is mainly used for performance testing and aging of online high-power UPS, inverter, switching power supply and diesel generator set of power, telecommunications and other departments and manufacturers.

1


PRODUCT OVERVIEW


600 kW load bank is mainly used for performance testing and aging of online high-power UPS, inverter, switching power supply and diesel generator set of power, telecommunications and other departments and manufacturers. AC 600 kW load bank has unified segmented power input, energy consumption working mode and forced air cooling heat dissipation, which greatly ensures the reliability of constant power discharge; The internal heat dissipation element adopts dry resistance and forced air cooling heat dissipation. AC 600 kW load bank is produced with independent intellectual property rights of new power consumption components, with high power density, no red heat phenomenon, automatic overheating protection function, no overheating and burning loss when the fan does not run, and long safety life; The AC dummy load machine adopts modular design, which is simple to operate and convenient to maintain; The 600kW load bank provides scientific detection means for high-power AC power supply equipment.


PRODUCT PICTURE




APPLICATION SCENARIO



PARTIAL PARAMETERS



Note: all parameters are for reference only and can be customized

Product name

variable load bank

Specifications

R600kW/400VAC/50Hz/PF1.0

Formation

One load bank(Including dry resistance load, electrical control components, measurement and control system)

Load step

According to customer needs

Load connection

Copper bar

Resistor

Each resistance element: insulation impedance DC1000V/100MΩ above

Withstand voltage ac 2000V for 5min

Resistance error of each resistance tube:±3 percent

Load control

Local manual control, local automatic control or remote automatic control can be selected

Loading accuracy

Less than or equal to 3 percent

Three phase balance

Unbalance degree less than or equal to 3 percent

Minimum step

1kW

Working mode

Continuous work

Load protection

Short circuit, overcurrent, high temperature, fan fault protection

External power

TN-C,380V/50Hz

Cooling mode

Forced air cooling, side air outlet or top air outlet

Insulation class

F

Measurement accuracy

The display accuracy is {{0}}.5,the sampling accuracy is 0.2

Electrical parameter display

Three phase voltage, three-phase current, frequency, power, etc

Load expansion

Parallel expansion of multiple load containers

Standard

Meet international standard, ship standard, military standard and telecommunication standard

Transport

The load bank is equipped with load-bearing lifting holes, and the bottom can be equipped with rollers to meet the requirements of long-distance transportation

Color

Customized

Ambient temperature

-20 degree to 50 degree

Humidity

Up to 100 percent

Altitude

Up to 2500m

Atmospheric pressure

86 to 106kPa


MORE SPECIFICATIONS



Note: all parameters are for reference only and can be customized

Power(kW)

Voltage(kV)

Frequency(Hz)

Size(mm,LWH)

Weight(Kg)

Low voltage

100

0.4

50

11009001000

320

200

0.4

50

135011001100

450

300

0.4

50

150012001200

650

400

0.4

50

170015001500

830

500

0.4

50

170016001600

950

600

0.4

50

180016001600

1150

800

0.4

50

190018001700

1900

1000

0.4

50

230017002100

2100

1200

0.4

50

250018002200

2300

1500

0.4

50

250018602300

2600

1800

0.4

50

300020002300

4000

2000

0.4

50

300020002300

5000

2500

0.4

50

400024382500

6000

3000

0.4

50

600024382500

7000

Medium voltage

1000

6/10.5

50/60

300024382500

3500

1200

6/10.5

50/60

400024382500

3900

1500

6/10.5

50/60

400024382500

4500

1600

6/10.5

50/60

500024382500

5000

1800

6/10.5

50/60

500024382500

6500

2000

6/10.5

50/60

600024382500

7500

2200

6/10.5

50/60

600024382500

8000

2500

6/10.5

50/60

600024382500

10000

3000

6/10.5

50/60

700024382500

12000

4000

6/10.5

50/60

800024382500

14000

5000

6/10.5

50/60

900024382500

15000

6000

6/10.5

50/60

1200024382500

16000

7000

6/10.5

50/60

1200024382500

17000

8000

6/10.5

50/60

1200024382500

18000


FACTORY ACCEPTANCE AND SITE ACCEPTANCE


Factory acceptance

Both parties may check and accept the system through actual operation.After the production of the system, the user shall be notified of the performance experiment before leaving the factory 3 days in advance, and the factory can pass the acceptance.Observe the following items during the acceptance inspection:

(1) The factory acceptance test shall be carried out in accordance with the technical agreement and the acceptance outline agreed by both parties.

(2) The Seller shall appoint technical backbone to provide technical services and training.

(3) When it first uses the system, the technicians involved in the acceptance will be fully guided and teach the methods.

(4) Guide users to install and debug according to technical data and drawings.

(5) The Seller is responsible for solving the problems arising in the manufacturing process.

(6) Factory acceptance test is only functional test, load test as the final acceptance item, in the user formal load test.

Site acceptance

After the system, the Seller sends personnel to the site for complete function and load test acceptance, including the following:

(1) The Seller is responsible for the transportation of the system and ensures that all accessories of the system reach the place designated by the user before the agreed date.

(2) The Seller shall be responsible for the site installation and commissioning of the system. The site acceptance test shall be conducted in accordance with the technical agreement and the acceptance outline agreed by both parties (the test unit and fuel are provided by the user) and guaranteed to be delivered to the user before the agreed date.

(3) The Seller provides relevant training for the user's technical personnel to meet the daily work and maintenance needs of the system.

(4) During the training, the Seller assigns experienced technical personnel as guidance, and develops a detailed training outline for theoretical and practical content (to provide electronic training courses and materials).

(5) Ensure that the trained personnel understand the working principle, operation methods, precautions, various abnormal response methods and daily maintenance methods of the system.


HONORARY QUALIFICATION


Since its establishment, Rata has obtained 16 utility model patent certificates and 8 computer software copyright registration certificates, and has been recognized as a national high-tech enterprise.



étiquette à chaud: 600 kw load bank, China, suppliers, manufacturers, factory, customized, price, quotation

(0/10)

clearall